1.
17th International Conference on Indoor Air Quality and Climate, INDOOR AIR 2022 ; 2022.
Article Dans Anglais | Scopus | ID: covidwho-2327194

Résumé

This study contributes to a better understanding of the airborne transmission risks in multizone, mechanically ventilated buildings and how to reduce infection risk. A novel modeling approach combining the Wells-Riley and the US National Institute of Standards and Technology (NIST) CONTAM models was applied to a multizone whole building to simulate exposure and assess the effectiveness of different mitigation measures. A case study for the US Department of Energy large office prototype building was conducted to illustrate the approach. © 2022 17th International Conference on Indoor Air Quality and Climate, INDOOR AIR 2022. All rights reserved.

2.
8th International Building Physics Conference, IBPC 2021 ; 2069, 2021.
Article Dans Anglais | Scopus | ID: covidwho-1592859

Résumé

Natural ventilation (NV) is a strategy of bioclimatic design to promote hygrothermal comfort and indoor air quality (IAQ). Nowadays, COVID-19 pandemic highlights the review of ventilation standards. In Mexico, the IAQ standard states a minimum of 6 ACH for educational buildings. ACH considers NV as an ideal piston flow and does not provide information of indoor airflow distribution. In this work, new age of air associated parameters are proposed, considering the indoor airflow distribution: the air renovation per hour (ARH) and the renovation parameter R. An isolated educational building located in a rural region is studied. Four window configurations of cross-ventilation are considered. All configurations have one windward window located at bottom. The configurations axial and upward have one leeward window at bottom and top, respectively. While, configurations corner and upward corner have one lateral side window at bottom and top, respectively. A CFD model of the educational building is validated with experiments. The axial configuration has the best performance according to ACH, nevertheless has the worst performance according to ARH and R. The results show that NV evaluation using ACH can lead to wrong decisions. An improvement of NV standard with the age of air associated parameters is recommended. © 2021 Institute of Physics Publishing. All rights reserved.

SÉLECTION CITATIONS
Détails de la recherche